Do you know the difference between ultrapure water equipment and pure water equipment?

Ultrapure water equipment is the use of pre-treatment, reverse osmosis technology, ultra-purification treatment and post-treatment methods, the conductive medium in the water is almost completely removed, and the water will not dissociate the colloidal substances, gases and organic matter are removed to a very low degree of water treatment equipment.

Pure water equipment, it is mainly reverse osmosis membrane technology. Its working principle is to exert a certain pressure on the water, so that the water molecules and ionic mineral elements through the reverse osmosis membrane, and dissolved in the water of the vast majority of inorganic salts (including heavy metals), organics, and bacteria, viruses, etc. can not pass through the reverse osmosis membrane, so that the infiltration of the pure water and can not be infiltrated through the concentration of the water is strictly separate; Reverse osmosis membrane pore size is only 0.0001 microns, and the viral The diameter of the reverse osmosis membrane is only 0.0001 microns, while the virus is generally 0.02-0.4 microns, the diameter of ordinary bacteria is 0.4-1 microns.

First, the use of different

(A) the use of ultrapure water equipment:
1, the production and cleaning of ultrapure materials and ultrapure reagents.
2, the production and cleaning of electronic products.
3, the production of battery products.
4, the production and cleaning of semiconductor products.
5、Production and cleaning of circuit boards.
6, the production of other high-tech fine products.

(B) the use of pure water equipment:
1, power plant chemical water treatment
2, electronics, semiconductors, precision machinery industry ultrapure water
3, food, beverage, drinking water preparation
4, small pure water station, group drinking pure water
5、Fine chemical industry, precision discipline water
6、Other industries required for the preparation of high-purity water
7、Pharmaceutical industry process water
8, seawater, brackish water desalination

Second, the conductivity of water is different
1. ultrapure water quality: resistivity > 15MΩ.cm ultrapure water quality is divided into five industry standards, respectively, 18MΩ.cm, 15MΩ.cm, 10MΩ.cm, 2MΩ.cm, 0.5MΩ.cm, in order to distinguish between different water quality.
2. Pure water is divided into: industrial pure water and drinking pure water industrial pure water: in 25 degrees Celsius, the
1. Ordinary pure water:EC=1~10us/cm; 2.
2. high purity water:EC=0.1~1.0us/cm; 3. ultra-pure water:EC=0.1~1.0us/cm.
3. ultrapure water:EC=0.1~0.055; drinking pure water:EC=1~10 us/cm(national standard).

III. Different processes used between the various types of equipment

(A) the process flow of ultrapure water equipment is:
1、Pre-treatment system → reverse osmosis system → intermediate water tank → coarse mixed bed → fine mixed bed → pure water tank → pure water pump → ultraviolet steriliser → polished mixed bed → precision filter → water object (≥18MΩ.CM) (traditional process).
2、Pre-treatment → reverse osmosis → intermediate water tank → water pump → EDI device → purified water tank → pure water pump → ultraviolet steriliser → polished mixed bed → 0.2 or 0.5μm precision filter → water object (≥18MΩ.CM) (the latest process).
3、Pre-treatment → first-stage reverse osmosis → dosing machine (PH adjustment) → intermediate water tank → second-stage reverse osmosis (positively charged reverse osmosis membrane) → pure water tank → pure water pump → EDI device → ultraviolet steriliser → 0.2 or 0.5 μm precision filter → water-using objects (≥17MΩ.CM) (the latest process).
4、Pre-treatment → reverse osmosis → intermediate water tank → water pump → EDI device → pure water tank → pure water pump → ultraviolet steriliser → 0.2 or 0.5μm precision filter → water object (≥15MΩ.CM) (the latest process).
5、Pre-treatment system → reverse osmosis system → intermediate tank → pure water pump → coarse mixed bed → fine mixed bed → ultraviolet steriliser → precision filter → water object (≥15MΩ.CM) (traditional process).

(ii) The process flow of pure water equipment is:

1, using ion exchange
Raw water → raw water pressure pump → multi-media filter → activated carbon filter → water softener → precision filter → positive resin filter bed → negative resin filter bed → anion and Yang resin mixing bed → microporous filter → water points

2、Adopting two-stage reverse osmosis
Raw water → raw water pressure pump → multi-media filter → activated carbon filter → water softener → precision filter → the first stage of reverse osmosis → PH adjustment → intermediate water tank → the second stage of reverse osmosis (reverse osmosis membrane surface positive charge) → purification tank → pure water pump → microporous filter → point of water use

3、Using EDI method
Raw water → raw water pressure pump → multi-media filter → activated carbon filter → water softener → precision filter → a reverse osmosis machine → intermediate water tank → intermediate water pump → EDI system → microporous filter → water points
Related News
Read More >>
Analysis of common problems of reverse osmosis water equipment operation Analysis of common problems of reverse osmosis water equipment operation
Oct .29.2024
Reverse osmosis equipment is an important part of pure water equipment, purified water equipment, ultrapure water equipment, and also equipment system operation is more prone to problems.
The following are common reverse osmosis equipment problems and causes.
Do you know what is the most reasonable recovery rate setting for RO system? Do you know what is the most reasonable recovery rate setting for RO system?
Oct .28.2024
When discussing design options with peers and customers, the question of the reasonableness of the system's recovery rate setting often comes up. The essence of the problem is to set the recovery rate has exceeded the upper limit of the recovery rate of the system (limit recovery rate).
Reverse osmosis ultrapure water equipment common faults (with solutions) Reverse osmosis ultrapure water equipment common faults (with solutions)
Oct .25.2024
Reverse osmosis ultrapure water equipment is a kind of equipment used to remove impurities and pollutants in water, but it is inevitable that it will encounter some problems in the course of its usual operation and use, so how should it solve these problems? The following are some common water purifier problems with corresponding solutions:
​​​​​​​Factors affecting the effectiveness of activated carbon filtration and methods of use ​​​​​​​Factors affecting the effectiveness of activated carbon filtration and methods of use
Oct .25.2024
​​​​​​​Factors affecting the effectiveness of activated carbon filtration and methods of use
The adsorption capacity of activated carbon is related to the water temperature and water quality.The adsorption principle of activated carbon。